Please use this identifier to cite or link to this item: 10.5937/jomb0-26008
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPikta, Marika-
dc.contributor.authorSzanto, Timea-
dc.contributor.authorViigimaa, Margus-
dc.contributor.authorLejniece, Sandra-
dc.contributor.authorBalode, Darta-
dc.contributor.authorSaks, Kadri-
dc.contributor.authorBanys, Valdas-
dc.date.accessioned2022-01-27T08:20:01Z-
dc.date.available2022-01-27T08:20:01Z-
dc.date.issued2021-
dc.identifier.citationPikta , M , Szanto , T , Viigimaa , M , Lejniece , S , Balode , D , Saks , K & Banys , V 2021 , ' Evaluation of a new semi-automated hydragel 11 von willebrand factor multimers assay kit for routine use ' , Journal of Medical Biochemistry , vol. 40 , no. 2 , pp. 167-172 . https://doi.org/10.5937/jomb0-26008-
dc.identifier.issn1452-8258-
dc.identifier.urihttps://dspace.rsu.lv/jspui/handle/123456789/7330-
dc.descriptionPublisher Copyright: © 2021 Sciendo. All rights reserved.-
dc.description.abstractBackground: Accurate diagnosis and classification of von Willebrand disease (VWD) are essential for optimal management. The von Willebrand factor multimers analysis (VWF:MM) is an integral part of the diagnostic process in the phenotypic classification, especially in discrepant cases. The aim of this study was to evaluate the performance of a new Hydragel 11VWF multimer assay (H11VW). Methods: Analytical performance characteristics such as repeatability (intra-assay variability, in gel between track variation), reproducibility (inter-assay variability, between gel variation), sensitivity, EQA performance and differences between two commercially available VWF:MM kits (H5VW and H11VW) were analysed in healthy volunteers' plasmas using in-house prepared reference plasma. Results: Repeatability and reproducibility results of H11VW demonstrated acceptable and equivalent performance with previously verified H5VW. Participation in EQA was successful. No statistically significant difference was detected between H5VW and H11VW kits for different fractions of multimers: LMWM p=0.807; IMWM p=0.183; HMWM p=0.774. Conclusions: H11VW demonstrated acceptable analytical performance characteristics. H11VW kit conveniently offers a more significant number of samples on a single gel. H5VW and H11VW kits can be used in daily practice interchangeably.en
dc.format.extent5-
dc.format.extent585666-
dc.language.isoeng-
dc.relation.ispartofJournal of Medical Biochemistry-
dc.rightsinfo:eu-repo/semantics/openAccess-
dc.subjectElectrophoresis-
dc.subjectMultimers-
dc.subjectVon Willebrand disease-
dc.subjectVon Willebrand factor-
dc.subject3.4 Medical biotechnology-
dc.subject1.6 Biological sciences-
dc.subject1.1. Scientific article indexed in Web of Science and/or Scopus database-
dc.subjectClinical Biochemistry-
dc.subjectBiochemistry, medical-
dc.titleEvaluation of a new semi-automated hydragel 11 von willebrand factor multimers assay kit for routine useen
dc.type/dk/atira/pure/researchoutput/researchoutputtypes/contributiontojournal/article-
dc.identifier.doi10.5937/jomb0-26008-
dc.contributor.institutionRīga Stradiņš University-
dc.identifier.urlhttp://www.scopus.com/inward/record.url?scp=85115047794&partnerID=8YFLogxK-
dc.description.statusPeer reviewed-
Appears in Collections:Research outputs from Pure / Zinātniskās darbības rezultāti no ZDIS Pure



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.