Please use this identifier to cite or link to this item: 10.2478/v10047-011-0014-9
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLogina, L.-
dc.contributor.authorKrievins, D.-
dc.contributor.authorDrevinska, K.-
dc.contributor.authorAuzans, A.-
dc.contributor.authorSvabe, L.-
dc.contributor.authorTimuhins, A.-
dc.date.accessioned2021-08-19T06:15:01Z-
dc.date.available2021-08-19T06:15:01Z-
dc.date.issued2011-01-01-
dc.identifier.citationLogina , L , Krievins , D , Drevinska , K , Auzans , A , Svabe , L & Timuhins , A 2011 , ' Ultraskaņas Ātruma Izmaiņa Kaulaudos Pēc Pārtrauktas Asinsrites ' , Latvian Journal of Physics and Technical Sciences , vol. 48 , no. 2 , pp. 44-49 . https://doi.org/10.2478/v10047-011-0014-9-
dc.identifier.issn0868-8257-
dc.identifier.urihttps://dspace.rsu.lv/jspui/handle/123456789/6040-
dc.description.abstractThe reported ultrasonic velocity measurements have been performed using a device in which the transmitter and the detector of sound vibrations are rigidly mounted at a constant distance from each other to avoid statistical errors at measuring the distance travelled by acoustic waves. The accuracy of measurements was thus dependent only on the resolution of the device determined by the frequency of time reference signals, its stability, the travelled distance, and the sound velocity.The velocities measured in six objects exhibit a common behaviour with time, reaching a maximum between the 9-th and 33-rd hour after complete disruption in the blood supply and remaining higher compared with the initial value at least for 80 h after disruption. The obtained values of sound velocity are consistent with the results found by other authors, while the rise after disruption in the blood supply - with the increase in elasticity of the bone tissue.en
dc.format.extent6-
dc.format.extent450909-
dc.language.isolav-
dc.relation.ispartofLatvian Journal of Physics and Technical Sciences-
dc.rightsinfo:eu-repo/semantics/openAccess-
dc.subject1.3 Physical sciences-
dc.subject2.6 Medical engineering-
dc.subject1.1. Scientific article indexed in Web of Science and/or Scopus database-
dc.subjectGeneral Engineering-
dc.subjectGeneral Physics and Astronomy-
dc.titleUltraskaņas Ātruma Izmaiņa Kaulaudos Pēc Pārtrauktas Asinsriteslv
dc.title.alternativeUltrasound velocity in bone under disrupted blood supplyen
dc.type/dk/atira/pure/researchoutput/researchoutputtypes/contributiontojournal/article-
dc.identifier.doi10.2478/v10047-011-0014-9-
dc.contributor.institutionRīga Stradiņš University-
dc.identifier.urlhttp://www.scopus.com/inward/record.url?scp=79957483572&partnerID=8YFLogxK-
dc.description.statusPeer reviewed-
Appears in Collections:Research outputs from Pure / Zinātniskās darbības rezultāti no ZDIS Pure

Files in This Item:


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.