Please use this identifier to cite or link to this item:
10.1155/2018/4804902
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Klimecs, Vadims | - |
dc.contributor.author | Grishulonoks, Alexanders | - |
dc.contributor.author | Salma, Ilze | - |
dc.contributor.author | Neimane, Laura | - |
dc.contributor.author | Locs, Janis | - |
dc.contributor.author | Šauriņa, Eva | - |
dc.contributor.author | Skagers, Andrejs | - |
dc.date.accessioned | 2021-07-16T11:30:01Z | - |
dc.date.available | 2021-07-16T11:30:01Z | - |
dc.date.issued | 2018 | - |
dc.identifier.citation | Klimecs , V , Grishulonoks , A , Salma , I , Neimane , L , Locs , J , Šauriņa , E & Skagers , A 2018 , ' Bone Loss around Dental Implants 5 Years after Implantation of Biphasic Calcium Phosphate (HAp/βTCP) Granules ' , Journal of Healthcare Engineering , vol. 2018 , 4804902 . https://doi.org/10.1155/2018/4804902 | - |
dc.identifier.issn | 2040-2295 | - |
dc.identifier.uri | https://dspace.rsu.lv/jspui/handle/123456789/5898 | - |
dc.description | Funding Information: +e study was supported by National Research Programme No. 2014.10-4/VPP-3/21 “Multifunctional Materials and Composites, Photonics and Nanotechnology (IMIS2)” Project No. 4 “Nanomaterials and Nanotechnologies for Medical Applications.” Publisher Copyright: © 2018 Vadims Klimecs et al. | - |
dc.description.abstract | Biphasic calcium phosphate ceramic granules (0.5-1.0 mm) with a hydroxyapatite and β-tricalcium phosphate ratio of 90/10 were used. Biphasic calcium phosphate ceramic granules produced in the Riga Technical University, Riga Rudolph Cimdins Biomaterials Innovation and Development Centre, were used for filling the bone loss on 18 patients with peri-implantitis. After 5 years at the minimum, clinical and 3D cone-beam computed tomography control was done. Clinical situation confirmed good stability of implants without any signs of inflammation around. Radiodensity of the previous gap and alveolar bone horizontally from middle point of dental implants showed similar radiodensity as in normal alveolar bone. | en |
dc.format.extent | 3775453 | - |
dc.language.iso | eng | - |
dc.relation.ispartof | Journal of Healthcare Engineering | - |
dc.rights | info:eu-repo/semantics/openAccess | - |
dc.subject | 3.4 Medical biotechnology | - |
dc.subject | 3.2 Clinical medicine | - |
dc.subject | 1.1. Scientific article indexed in Web of Science and/or Scopus database | - |
dc.subject | Biotechnology | - |
dc.subject | Surgery | - |
dc.subject | Biomedical Engineering | - |
dc.subject | Health Informatics | - |
dc.title | Bone Loss around Dental Implants 5 Years after Implantation of Biphasic Calcium Phosphate (HAp/βTCP) Granules | en |
dc.type | /dk/atira/pure/researchoutput/researchoutputtypes/contributiontojournal/article | - |
dc.identifier.doi | 10.1155/2018/4804902 | - |
dc.contributor.institution | Department of Doctoral Studies | - |
dc.contributor.institution | Department of Oral and Maxillofacial Surgery and Oral Medicine | - |
dc.contributor.institution | Rīga Stradiņš University | - |
dc.contributor.institution | Statistics Unit | - |
dc.identifier.url | http://www.scopus.com/inward/record.url?scp=85058882122&partnerID=8YFLogxK | - |
dc.description.status | Peer reviewed | - |
Appears in Collections: | Research outputs from Pure / Zinātniskās darbības rezultāti no ZDIS Pure |
Files in This Item:
File | Size | Format | |
---|---|---|---|
Bone_Loss_around_Dental_Implants.pdf | 3.69 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.