Full metadata record
DC FieldValueLanguage
dc.contributor.advisorGuna Semjonova-
dc.contributor.authorAnna Davidoviča-
dc.contributor.otherRehabilitācijas fakultātelv-LV
dc.contributor.otherFaculty of Rehabilitationen-UK
dc.date.accessioned2022-08-16T14:05:00Z-
dc.date.available2022-08-16T14:05:00Z-
dc.date.issued2022-
dc.identifier.urihttps://dspace.rsu.lv/jspui/handle/123456789/9043-
dc.descriptionRehabilitācijalv-LV
dc.descriptionRehabilitationen-UK
dc.descriptionVeselības aprūpelv-LV
dc.descriptionHealth Careen-UK
dc.description.abstractDarba nosaukums: Viedā tekstilmateriāla zeķu spiediena sensoru sistēma paškorekcijas veikšanai sportistiem funkcionālo uzdevumu laikā: formatīva lietojamības novērtēšana Darba mērķis: Novērtēt viedā tekstilmateriāla zeķu spiediena sensoru sistēmas formatīvo lietojamību paškorekcijas veikšanai sportistiem funkcionālo uzdevumu laikā. Darba uzdevumi: 1. Novērtēt viedā tekstilmateriāla zeķu spiediena sensoru sistēmas lietošanas efektivitāti sportistiem paškorekcijas veikšanai funkcionālo uzdevumu laikā. 2. Novērtēt viedā tekstilmateriāla zeķu spiediena sensoru sistēmas lietderību sportistiem paškorekcijas veikšanai funkcionālo uzdevumu laikā. 3. Novērtēt viedā tekstilmateriāla zeķu spiediena sensoru sistēmas lietotāju apmierinātību paškorekcijas veikšanai sportistiem funkcionālo uzdevumu laikā. Pētnieciskais jautājums: Kāda ir formatīvā lietojamība viedā tekstilmateriāla zeķu spiediena sensoru sistēmai paškorekcijas veikšanai sportistiem funkcionālo uzdevumu laikā? Pētījuma metodes: Pētījumā, kurā iekļauta sistēmas formatīva lietojamības novērtēšana, piedalījās pieci sportisti no futbola skolas FS “LU Metta”. Sportistiem mijiedarbojoties ar sistēmu bija jāveic iepriekš definētie funkcionālie uzdevumi paškorekcijas veikšanai. Formatīvās lietojamības novērtēšanas metodes: 1. Efektivitāte (uzdevumu izpildes līmenis, kļūdu biežums); 2. Lietderība (uzdevumu izpildes laiks – kopējā relatīvā lietderība, uz laiku balstīta lietderība); 3. Atgriezeniskās saites sniegšana no lietotāja (apmierinātība) Sistēmas Lietojamības skala (angļu val. System Usability scale – SUS) un daļēji strukturētas intervijas metode (audio ieraksts). Pētījuma rezultāti: Formatīvās lietojamības iegūtie rādītāji: uzdevuma izpildes efektivitātes diapazons no 40% līdz 100% pirmā un otrā posma uzdevumos. Lietderība pēc uzdevuma izpildes laika: 1.posmā no 4.2s (SN 1.3) līdz 88.8s (SN 19.8); 2.posmā no 7.2s (SN 1.9) līdz 9.6 (SN 2.1). Apmierinātība vērtēta pēc SUS sistēmas lietotāju grupai ir 76 punkti (SN 7.42), kas liecina par “labu” apmierinātību. Secinājumi: Iegūtie formatīvās lietojamības rādītāji norāda uz nepieciešamību veikt viedā tekstilmateriāla zeķu spiediena sensoru sistēmas tehniskus uzlabojumus. SUS rezultāti norāda uz “labu” apmierinātību par viedā tekstilmateriāla zeķu spiediena sensoru sistēmu un tās lietotni.lv-LV
dc.description.abstractSubject: Smart textile sock pressure sensor system for athletes’ self-correction during functional tasks: formative usability evaluation Objective: To evaluate formative usability of the smart textile sock pressure sensor system for self-correction in athletes during functional tasks. Research tasks: 1. Evaluate the effectiveness of the use of smart textile sock pressure sensor system for athletes to perform self-correction during functional tasks. 2. Evaluate the efficiency for smart textile sock pressure sensor system for athletes to perform self-correction during functional tasks. 3. Evaluate the satisfaction of smart textile sock pressure sensor system users. Research question: What is the formative usability of the smart textile sock pressure sensor system for athletes’ self-correction during functional tasks? Research methods: Five athletes from the football school FS “LU Metta” participated in the formative usability study. Athletes perform pre-defined functional tasks for self-correction when interacting with the system. Formative usability evaluation methods: 1. Effectiveness (task success rate, error rate); 2. Efficiency (task completion time – total relative efficiency, time-based efficiency); 3. Providing biofeedback from the user (satisfaction) (System Usability scale) and semi- structured interview method (audio recording). Results: Formative usability indicators: the range of task execution effectiveness from 40% to 100% in the first and second stage tasks. Efficiency after the task execution time: in the 1st stage from 4.2s (SD 1.3) to 88.8s (SD 19.8); Stage 2 from 7.2s (SD 1.9) to 9.6 (SD 2.1). Satisfaction is assessed by the SUS system user group with 76 points (SD 7.42), which indicates “good” satisfaction. Conclusions: The obtained formative usability indicators indicate the need for technical improvements of the smart textile sock pressure sensor system. The SUS results indicate “good” satisfaction with the smart textile sock pressure sensor system and its application.en-UK
dc.language.isolv-LV-
dc.publisherRīgas Stradiņa universitātelv-LV
dc.publisherRīga Stradiņš Universityen-UK
dc.rightsinfo:eu-repo/semantics/restrictedAccess-
dc.subjectLietojamībalv-LV
dc.subjectviedā tekstilmateriāla zeķu spiediena sensoru sistēmalv-LV
dc.subjectpaškorekcijalv-LV
dc.subjectsportistilv-LV
dc.subjectatgriezeniskā saitelv-LV
dc.subjectUsabilityen-UK
dc.subjectsmart textile sock pressure sensor systemen-UK
dc.subjectself-correctionen-UK
dc.subjectathletesen-UK
dc.subjectbiofeedbacken-UK
dc.titleViedā tekstilmateriāla zeķu spiediena sensoru sistēma paškorekcijas veikšanai sportistiem funkcionālo uzdevumu laikā: formatīva lietojamības novērtēšanalv-LV
dc.title.alternativeSmart textile sock pressure sensor system for athletes self-correction during functional tasks: formative usability evaluationen-UK
dc.typeinfo:eu-repo/semantics/masterThesisen-UK
Appears in Collections:Maģistra darbi



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.