Data on analysis of MK-801 bioavailability in mouse plasma and brain tissue by ultra-performance liquid chromatography-tandem mass spectrometry
dc.contributor.author | Svalbe, Baiba | |
dc.contributor.author | Grinberga, Solveiga | |
dc.contributor.author | Stelfa, Gundega | |
dc.contributor.author | Vavers, Edijs | |
dc.contributor.author | Zvejniece, Baiba | |
dc.contributor.author | Sevostjanovs, Eduards | |
dc.contributor.author | Dambrova, Maija | |
dc.contributor.author | Zvejniece, Liga | |
dc.contributor.institution | Rīga Stradiņš University | |
dc.date.accessioned | 2021-04-28T07:50:02Z | |
dc.date.available | 2021-04-28T07:50:02Z | |
dc.date.issued | 2019-12 | |
dc.description | Funding Information: This research was supported by the European Regional Development Fund (ERDF) project No. 1.1.1.2/VIAA/1/16/244 “The role of sigma-1 receptor in sexual behavior”. Publisher Copyright: © 2019 The Author(s) | |
dc.description.abstract | MK-801, a N-methyl-D-aspartate receptor antagonist, is widely used in animal preclinical experiments to induce memory and learning impairments and schizophrenia-like behavior. In the present study, we compared the plasma and brain tissue concentrations of MK-801 after intraperitoneal (i.p.) or subcutaneous (s.c.) administration at a dose of 0.1 mg/kg in male ICR mice. Moreover, these data present the optimization of ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for the analysis of MK-801 in biological samples. Procedures for the preparation of brain tissue and plasma samples and instrumental analysis are described. This article is related to a research article entitled “Effects of the N-methyl-D-aspartate receptor antagonist, MK-801, on spatial memory and influence of the route of administration” [1]. | en |
dc.description.status | Peer reviewed | |
dc.format.extent | 456019 | |
dc.identifier.citation | Svalbe, B, Grinberga, S, Stelfa, G, Vavers, E, Zvejniece, B, Sevostjanovs, E, Dambrova, M & Zvejniece, L 2019, 'Data on analysis of MK-801 bioavailability in mouse plasma and brain tissue by ultra-performance liquid chromatography-tandem mass spectrometry', Data in Brief, vol. 27, 104623. https://doi.org/10.1016/j.dib.2019.104623 | |
dc.identifier.doi | 10.1016/j.dib.2019.104623 | |
dc.identifier.issn | 2352-3409 | |
dc.identifier.uri | https://dspace.rsu.lv/jspui/handle/123456789/3949 | |
dc.identifier.url | http://www.scopus.com/inward/record.url?scp=85068505948&partnerID=8YFLogxK | |
dc.language.iso | eng | |
dc.relation.ispartof | Data in Brief | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | Bioavailability | |
dc.subject | i.p. and s.c. administration route | |
dc.subject | Mice | |
dc.subject | MK-801 | |
dc.subject | UPLC-MS/MS | |
dc.subject | 3.1 Basic medicine | |
dc.subject | 1.1. Scientific article indexed in Web of Science and/or Scopus database | |
dc.subject | General | |
dc.title | Data on analysis of MK-801 bioavailability in mouse plasma and brain tissue by ultra-performance liquid chromatography-tandem mass spectrometry | en |
dc.type | /dk/atira/pure/researchoutput/researchoutputtypes/contributiontojournal/article |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Data_on_analysis_of_MK_801_bioavailability.pdf
- Size:
- 445.33 KB
- Format:
- Adobe Portable Document Format