Please use this identifier to cite or link to this item: 10.13107/jocr.2021.v11.i06.2234
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPetronis, Sandris-
dc.contributor.authorJakusonoka, Ruta-
dc.contributor.authorLinovs, Viktors-
dc.contributor.authorJumtins, Andris-
dc.date.accessioned2022-08-16T21:03:17Z-
dc.date.available2022-08-16T21:03:17Z-
dc.date.issued2021-06-
dc.identifier.citationPetronis , S , Jakusonoka , R , Linovs , V & Jumtins , A 2021 , ' Filling Bone Defects after Hip Arthroplasty Revision Using Hydroxyapatite/β-tricalcium Phosphate : A Case Report with Long-term Result ' , Journal of orthopaedic case reports , vol. 11 , no. 6 , pp. 5-9 . https://doi.org/10.13107/jocr.2021.v11.i06.2234-
dc.identifier.issn2250-0685-
dc.identifier.otherPubMedCentral: PMC9009477-
dc.identifier.urihttps://dspace.rsu.lv/jspui/handle/123456789/9424-
dc.descriptionCopyright: © Indian Orthopaedic Research Group.-
dc.description.abstractIntroduction: The increasing number of primary total hip replacements means that there is an increased need for hip arthroplasty revisions. The periprosthetic fractures which cause bone defects can occur during removal of the femoral component and healing of these fractures can be delayed. In femoral bone defects during revisions, there are no metal augments for filling these defects. Case Report: Fifty-nine-year-old female presented with infected loosening of the left hip non-cemented endoprosthesis 5 years after surgery. The patient underwent removal of endoprosthesis. In 2 months, re-implantation of non-cemented endoprosthesis was performed and biphasic calcium phosphate (BCP) ceramic granules with hydroxyapatite/β-tricalcium phosphate (HAp/β-TCP) were implanted in the femoral bone defects. Eleven months following the arthroplasty patient had periprosthetic fracture of the distal third of the left femur. The osteosynthesis was performed and BCP ceramic granules with HAp/β-TCP were used to fill the bone defect. Long-term follow-up showed very good functional outcome and bone defect healing. Conclusion: The BCP ceramic granules with HAp/β-TCP material adjusted to the bone defect anatomy, showed effective femoral bone defect and periprosthetic fracture healing in a patient with hip arthroplasty revision and periprosthetic fracture.en
dc.format.extent5-
dc.format.extent7455192-
dc.language.isoeng-
dc.relation.ispartofJournal of orthopaedic case reports-
dc.rightsinfo:eu-repo/semantics/openAccess-
dc.subjectbone defects-
dc.subjectfemoral-
dc.subjectrevision-
dc.subject3.2 Clinical medicine-
dc.subject1.1. Scientific article indexed in Web of Science and/or Scopus database-
dc.titleFilling Bone Defects after Hip Arthroplasty Revision Using Hydroxyapatite/β-tricalcium Phosphate : A Case Report with Long-term Resulten
dc.type/dk/atira/pure/researchoutput/researchoutputtypes/contributiontojournal/article-
dc.identifier.doi10.13107/jocr.2021.v11.i06.2234-
dc.contributor.institutionDepartment of Orthopaedics-
dc.identifier.urlhttps://www.webofscience.com/wos/alldb/full-record/MEDLINE:35437485-
dc.description.statusPeer reviewed-
Appears in Collections:Research outputs from Pure / Zinātniskās darbības rezultāti no ZDIS Pure



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.