The Influence of Bowel Preparation on ADC Measurements: Comparison between Conventional DWI and DWIBS Sequences
dc.contributor.author | Apine, Ilze | |
dc.contributor.author | Baduna, Monta | |
dc.contributor.author | Pitura, Reinis | |
dc.contributor.author | Pokrotnieks, Juris | |
dc.contributor.author | Krumina, Gaida | |
dc.contributor.institution | Department of Radiology | |
dc.contributor.institution | Rīga Stradiņš University | |
dc.contributor.institution | Department of Internal Diseases | |
dc.date.accessioned | 2021-05-31T12:15:01Z | |
dc.date.available | 2021-05-31T12:15:01Z | |
dc.date.issued | 2019-07 | |
dc.description.abstract | Background and objectives: The aim of the study was to assess whether there were di ff erences between apparent di ff usion coe ffi cient (ADC) values of di ff usion-weighted imaging (DWI) and di ff usion-weighted imaging with background body signal suppression (DWIBS) sequences in non-prepared and prepared bowels before and after preparation with an enteric hyperosmolar agent, to assess whether ADC measurements have the potential to avoid bowel preparation and whether ADC-DWIBS has advantages over ADC-DWI. Materials and Methods: 106 adult patients without evidence of inflammatory bowel disease (IBD) underwent magnetic resonance (MR) enterography before and after bowel preparation. ADC-DWI and ADC-DWIBS values were measured in the intestinal and colonic walls demonstrating high signal intensity (SI) at DWI tracking images of b = 800 s /mm2 before and after preparation. Results: There were significant di ff erence (p < 0.0001) in both ADC-DWI and ADC-DWIBS results between non-prepared and prepared jejunum for DWI being 1.09 x 10 3 mm2 /s and 1.76 x 10 3 mm2 /s, respectively, and for DWIBS being 0.91 x 10 3 mm2 /s and 1.75 x 10 3 mm2 /s, respectively. Both ADC-DWI and DWIBS also showed significant di ff erence between non-prepared and prepared colon (p < 0.0001), with DWI values 1.41 x 10 3 mm2 /s and 2.13 x 10 3 mm2 /s, and DWIBS-1.01 x 10 3mm2 /s and 2.04 x 10 3mm2 /s, respectively. Nosignificant di ff erence between ADC-DWI and ADC-DWIBS was found in prepared jejunum (p = 0.84) and prepared colon (p = 0.58), whereas a significant di ff erence was found in non-prepared jejunum and non-prepared colon (p = 0.0001 in both samples). Conclusions: ADC between DWI and DWIBS does not di ff er in prepared bowel walls but demonstrates a di ff erence in non-prepared bowel. ADC in non-prepared bowel is lower than in prepared bowel and possible overlap with the ADC range of IBD is possible in non-prepared bowel. ADC-DWIBS has no advantage over ADC-DWI in regard to IBD assessment. | en |
dc.description.status | Peer reviewed | |
dc.format.extent | 2885120 | |
dc.identifier.citation | Apine, I, Baduna, M, Pitura, R, Pokrotnieks, J & Krumina, G 2019, 'The Influence of Bowel Preparation on ADC Measurements: Comparison between Conventional DWI and DWIBS Sequences', Medicina (Kaunas), vol. 55, no. 7, 394. https://doi.org/10.3390/medicina55070394 | |
dc.identifier.doi | 10.3390/medicina55070394 | |
dc.identifier.issn | 1010-660X | |
dc.identifier.uri | https://dspace.rsu.lv/jspui/handle/123456789/4601 | |
dc.language.iso | eng | |
dc.relation.ispartof | Medicina (Kaunas) | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | MR enterography | |
dc.subject | MRE | |
dc.subject | diffusion-weighted imaging | |
dc.subject | DWI | |
dc.subject | DWIBS | |
dc.subject | ADC | |
dc.subject | 3.2 Clinical medicine | |
dc.subject | 1.1. Scientific article indexed in Web of Science and/or Scopus database | |
dc.title | The Influence of Bowel Preparation on ADC Measurements: Comparison between Conventional DWI and DWIBS Sequences | en |
dc.type | /dk/atira/pure/researchoutput/researchoutputtypes/contributiontojournal/article |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- The_Influence_of_Bowel_Preparation_on_ADC.pdf
- Size:
- 2.75 MB
- Format:
- Adobe Portable Document Format