2L of Polyethylene Glycol as the Main Small Bowel Cleansing Regimen Component Prior to Video Capsule Endoscopy : Interim Analysis

dc.contributor.authorDerovs, Aleksejs
dc.contributor.authorDerova, Jeļena
dc.contributor.authorKleina, Regīna
dc.contributor.authorPokrotnieks, Juris
dc.contributor.institutionRīga Stradiņš University
dc.date.accessioned2023-01-17T09:30:02Z
dc.date.available2023-01-17T09:30:02Z
dc.date.issued2020-05-26
dc.description.abstractCapsule Enteroscopy (CE) is a fundamentally new method in diagnostic endoscopy. However, there are several factors influencing the quality of this procedure, including impermeable fluids, food remains etc. The aim of the study was to assess one of the most popular currently used bowel preparation methods and evaluate possible effects of various factors. 136 CE examinations were analysed. Each patient was prepared using 2 litres of polyethylene glycol (PEG) one day prior to examination. There was a special form filled in for each patient, which included relevant parameters (anamnesis, CE data etc.). Of 136 CE cases, 84 (61.8%) were female patients and 52 (38.2%) were male. The small bowel (SB) transit time in 112 patients varied from 39 to 502 minutes, but in 24 cases the capsule did not reach caecum. The degree of bowel cleanliness was as follows: very good - 30 (22.1%) patients, satisfactory - 97 (71.3%), and poor - 9 (6.6%). A positive correlation was observed between the degree of SB cleanliness and the SB transit time (p = 0.015). A longer SB transits time was associated with poor SB cleanliness. The results obtained in this study showed that the quality of SB cleanliness is affected by SB transit time. A relatively large percentage of cases rated as satisfactory bowel cleanliness and comparatively small percentage of bowel cleanliness cases rated as "very good" were observed when 2 litres of PEG were used prior to CE, indicating an important issues in preparation of the bowel prior to CE.en
dc.description.statusPeer reviewed
dc.format.extent5
dc.format.extent97106
dc.identifier.citationDerovs, A, Derova, J, Kleina, R & Pokrotnieks, J 2020, '2L of Polyethylene Glycol as the Main Small Bowel Cleansing Regimen Component Prior to Video Capsule Endoscopy : Interim Analysis', Proceedings of the Latvian Academy of Sciences, Section B: Natural, Exact, and Applied Sciences, vol. 74, no. 2, pp. 83-87. https://doi.org/10.2478/prolas-2020-0013
dc.identifier.doi10.2478/prolas-2020-0013
dc.identifier.issn2255-890X
dc.identifier.otherMendeley: 9c16e5ab-6804-3bad-b1a3-ae6f7d9741bf
dc.identifier.urihttps://dspace.rsu.lv/jspui/handle/123456789/10092
dc.identifier.urlhttps://www.mendeley.com/catalogue/9c16e5ab-6804-3bad-b1a3-ae6f7d9741bf/
dc.identifier.urlhttp://www.scopus.com/inward/record.url?scp=85110391448&partnerID=8YFLogxK
dc.language.isoeng
dc.relation.ispartofProceedings of the Latvian Academy of Sciences, Section B: Natural, Exact, and Applied Sciences
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectcapsule endoscopy
dc.subjecttransit time
dc.subjectbowel cleanliness
dc.subjectbowel preparation
dc.subject3.2 Clinical medicine
dc.subject1.1. Scientific article indexed in Web of Science and/or Scopus database
dc.title2L of Polyethylene Glycol as the Main Small Bowel Cleansing Regimen Component Prior to Video Capsule Endoscopy : Interim Analysisen
dc.type/dk/atira/pure/researchoutput/researchoutputtypes/contributiontojournal/article

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
2L_OF_POLYETHYLENE_GLYCOL.pdf
Size:
94.83 KB
Format:
Adobe Portable Document Format