Bone Loss around Dental Implants 5 Years after Implantation of Biphasic Calcium Phosphate (HAp/βTCP) Granules

dc.contributor.authorKlimecs, Vadims
dc.contributor.authorGrishulonoks, Alexanders
dc.contributor.authorSalma, Ilze
dc.contributor.authorNeimane, Laura
dc.contributor.authorLocs, Janis
dc.contributor.authorŠauriņa, Eva
dc.contributor.authorSkagers, Andrejs
dc.contributor.institutionDepartment of Doctoral Studies
dc.contributor.institutionDepartment of Oral and Maxillofacial Surgery and Oral Medicine
dc.contributor.institutionRīga Stradiņš University
dc.contributor.institutionStatistics Unit
dc.date.accessioned2021-07-16T11:30:01Z
dc.date.available2021-07-16T11:30:01Z
dc.date.issued2018
dc.descriptionFunding Information: +e study was supported by National Research Programme No. 2014.10-4/VPP-3/21 “Multifunctional Materials and Composites, Photonics and Nanotechnology (IMIS2)” Project No. 4 “Nanomaterials and Nanotechnologies for Medical Applications.” Publisher Copyright: © 2018 Vadims Klimecs et al.
dc.description.abstractBiphasic calcium phosphate ceramic granules (0.5-1.0 mm) with a hydroxyapatite and β-tricalcium phosphate ratio of 90/10 were used. Biphasic calcium phosphate ceramic granules produced in the Riga Technical University, Riga Rudolph Cimdins Biomaterials Innovation and Development Centre, were used for filling the bone loss on 18 patients with peri-implantitis. After 5 years at the minimum, clinical and 3D cone-beam computed tomography control was done. Clinical situation confirmed good stability of implants without any signs of inflammation around. Radiodensity of the previous gap and alveolar bone horizontally from middle point of dental implants showed similar radiodensity as in normal alveolar bone.en
dc.description.statusPeer reviewed
dc.format.extent3775453
dc.identifier.citationKlimecs, V, Grishulonoks, A, Salma, I, Neimane, L, Locs, J, Šauriņa, E & Skagers, A 2018, 'Bone Loss around Dental Implants 5 Years after Implantation of Biphasic Calcium Phosphate (HAp/βTCP) Granules', Journal of Healthcare Engineering, vol. 2018, 4804902. https://doi.org/10.1155/2018/4804902
dc.identifier.doi10.1155/2018/4804902
dc.identifier.issn2040-2295
dc.identifier.urihttps://dspace.rsu.lv/jspui/handle/123456789/5898
dc.identifier.urlhttp://www.scopus.com/inward/record.url?scp=85058882122&partnerID=8YFLogxK
dc.language.isoeng
dc.relation.ispartofJournal of Healthcare Engineering
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subject3.4 Medical biotechnology
dc.subject3.2 Clinical medicine
dc.subject1.1. Scientific article indexed in Web of Science and/or Scopus database
dc.subjectBiotechnology
dc.subjectSurgery
dc.subjectBiomedical Engineering
dc.subjectHealth Informatics
dc.titleBone Loss around Dental Implants 5 Years after Implantation of Biphasic Calcium Phosphate (HAp/βTCP) Granulesen
dc.type/dk/atira/pure/researchoutput/researchoutputtypes/contributiontojournal/article

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Bone_Loss_around_Dental_Implants.pdf
Size:
3.6 MB
Format:
Adobe Portable Document Format