Repository logo
  • English
  • Latviešu
  • Log In
    New user? Click here to register. Have you forgotten your password?
Repository logo
  • Communities & Collections
  • All of DSpace
  • English
  • Latviešu
  • Log In
    New user? Click here to register. Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Kalejs, Martins"

Now showing 1 - 5 of 5
Results Per Page
Sort Options
  • No Thumbnail Available
    Item
    Comparison of outcome between blood culture positive and negative infective endocarditis patients undergoing cardiac surgery
    (2021-05-27) Meidrops, Kristians; Zuravlova, Arina; Osipovs, Janis Davis; Kalejs, Martins; Groma, Valerija; Petrosina, Eva; Reinis, Aigars; Strike, Eva; Dumpis, Uga; Erglis, Andrejs; Stradins, Peteris; Rīga Stradiņš University; Statistics Unit; Department of Biology and Microbiology
    Background: Up to 30% or even more of all infective endocarditis (IE) cases are recognized as blood culture negative, meaning that the causative agent is left unidentified. The prompt diagnosis together with the identification of causative microorganism and targeted antibiotic treatment can significantly impact the prognosis of the disease and further patient’s health status. In some studies, blood culture negative endocarditis has been shown to be associated with delayed diagnosis, worse outcome and course of the disease, and a greater number of intra and postoperative complications. Methods: We retrospectively analysed the medical records of all patients who underwent cardiac surgery for endocarditis between years 2016 and 2019. The aim of this study was to analyse short and long-term mortality and differences of laboratory, clinical and echocardiography parameters in patients with blood culture positive endocarditis (BCPE) and blood culture negative endocarditis (BCNE) and its possible impact on the clinical outcome. Results: In our study population were 114 (55.1%) blood culture positive and 93 (44.9%) blood culture negative cases of infectious endocarditis. The most common pathogens in the blood culture positive IE group were S.aureus in 36 cases (31.6%), Streptococcus spp. in 27 (23.7%), E.faecalis in 24 (21.1%), and other microorganisms in 27 (23.7%). Embolic events were seen in 60 patients (28.9%). In univariate analyses, detection of microorganism, elevated levels of procalcitonin were found to be significantly associated with intrahospital death, however it did not reach statistical significance in multivariate analyses. Among microorganisms, S.aureus was significantly associated with intrahospital death in both univariate and multivariate analyses. Conclusions: There are no statistically significant differences between groups of BCPE and BCNE in terms of intrahospital mortality, hospital and ICU stay or 3-year mortality. There were higher levels of procalcitonin in BCPE group, however procalcitonin failed to show independent association with mortality in multivariate analysis. The most common microorganism in the BCPE group was S.aureus. It was associated with independently higher intrahospital mortality when compared to other causative microorganisms.
  • No Thumbnail Available
    Item
    Four-Year Outcomes of Left Main Percutaneous Coronary Intervention with a Bioresorbable Scaffold in the Circumflex Ostium
    (2022) Erglis, Andrejs; Narbute, Inga; Sondore, Dace; Jegere, Sanda; Kumsars, Indulis; Dombrovskis, Andis; Grikis, Karlis; Briede, Ieva; Dombrovska, Kristine; Trusinskis, Karlis; Grave, Alona; Erglis, Martins; Kalejs, Martins; Stradins, Peteris; Strazdins, Uldis; Rīga Stradiņš University
    Objectives. The study aimed to investigate the long-term outcomes of a double stent scaffold strategy in patients with left main (LM) bifurcation lesions involving the ostium of the left circumflex artery (LCX), utilizing a drug-eluting stent (DES) in the LM extending into the left anterior descending artery (LAD) and a bioresorbable vascular scaffold (BVS) in the LCX ostium. Background. The high occurrence of in-stent restenosis of the LCX ostium is the major limitation of percutaneous coronary intervention (PCI) for LM lesions with a two-stent strategy. Methods. This was a single-center, prospective, single-arm study of 46 consecutively enrolled patients with a stable coronary artery disease and significant unprotected LM distal bifurcation disease. Patients underwent imaging-guided PCI using DES in the LM-LAD and BVS in the LCX using a T-stent or mini-crush technique. The primary outcome at four years was the composite of death, myocardial infarction, stroke, and target lesion revascularization (TLR). Results. At four years, the primary outcome was identified in 9 patients (19.6%). All events were TLRs except one myocardial infarction due to BVS thrombosis. Seven of the eight TLRs were a result of side branch BVS restenosis. Univariate predictors of the 4-year outcome were higher LDL cholesterol and BVS size ≤2.5 mm. On multivariate analysis, LCX lesion preparation with a cutting balloon and post-procedure use of intravascular ultrasound for optimization were found to be independent protective factors of MACE. Conclusions. In selected patients with LM distal bifurcation disease, an imaging-guided double stent scaffold strategy with DES in the LM and BVS in the LCX ostium was technically successful in all patients and was reasonably safe and effective for four years.
  • No Thumbnail Available
    Item
    The fusion of tissue spheroids attached to pre-stretched electrospun polyurethane scaffolds
    (2014-01-17) Beachley, Vince; Kasyanov, Vladimir; Nagy-Mehesz, Agnes; Norris, Russell; Ozolanta, Iveta; Kalejs, Martins; Stradins, Peteris; Baptista, Leandra; da Silva, Karina; Grainjero, Jose; Wen, Xuejun; Mironov, Vladimir; Biomehānikas zinātniskā laboratorija
    Effective cell invasion into thick electrospun biomimetic scaffolds is an unsolved problem. One possible strategy to biofabricate tissue constructs of desirable thickness and material properties without the need for cell invasion is to use thin (<2 µm) porous electrospun meshes and self-assembling (capable of tissue fusion) tissue spheroids as building blocks. Pre-stretched electrospun meshes remained taut in cell culture and were able to support tissue spheroids with minimal deformation. We hypothesize that elastic electrospun scaffolds could be used as temporal support templates for rapid self-assembly of cell spheroids into higher order tissue structures, such as engineered vascular tissue. The aim of this study was to investigate how the attachment of tissue spheroids to pre-stretched polyurethane scaffolds may interfere with the tissue fusion process. Tissue spheroids attached, spread, and fused after being placed on pre-stretched polyurethane electrospun matrices and formed tissue constructs. Efforts to eliminate hole defects with fibrogenic tissue growth factor-β resulted in the increased synthesis of collagen and periostin and a dramatic reduction in hole size and number. In control experiments, tissue spheroids fuse on a non-adhesive hydrogel and form continuous tissue constructs without holes. Our data demonstrate that tissue spheroids attached to thin stretched elastic electrospun scaffolds have an interrupted tissue fusion process. The resulting tissue-engineered construct phenotype is a direct outcome of the delicate balance of the competing physical forces operating during the tissue fusion process at the interface of the pre-stretched elastic scaffold and the attached tissue spheroids. We have shown that with appropriate treatments, this process can be modulated, and thus, a thin pre-stretched elastic polyurethane electrospun scaffold could serve as a supporting template for rapid biofabrication of thick tissue-engineered constructs without the need for cell invasion.
  • No Thumbnail Available
    Item
    Lead-related infective endocarditis in Latvia : A single centre experience
    (2019-09) Nesterovics, Nikolajs; Nesterovics, Georgijs; Stradins, Peteris; Kalejs, Martins; Ansabergs, Janis; Blumbergs, Maris; Maca, Aija; Kamzola, Ginta; Lejnieks, Aivars; Kalejs, Oskars; Erglis, Andrejs; Rīga Stradiņš University; Faculty of Medicine
    Background and Objectives: Over the last five decades cardiac implantable electronic devices (CIED) have become established as the mainstay for the treatment of permanent bradycardias, chronic heart failure and dangerous heart rhythm disturbances. These devices improve survival and quality of life in many patients. However, infections associated with CIED implantation, particularly lead-related infective endocarditis (LRIE), can offset all benefits and make more harm than good for the patient. To date, there are no other studies in Latvia, addressing patients with lead-related infective endocarditis. The objective of this study was to identify the most common pathogens associated with LRIE and their antimicrobial resistance and to identify possible risk factors of patients who present with LRIE. Materials and Methods: The study was performed retrospectively at Pauls Stradins Clinical University Hospital (PSCUH). The study included patients who were referred to PSCUH due to LRIE for lead extraction. Patients were identified from procedural journals. Information about isolated microorganisms, patient comorbidities and visual diagnostics data was taken from patient records. Results: Forty-nine patients with CIED related infective endocarditis were included in the study, 34 (69.4%) were male, median age of all patients was 65.0 (50.5–73.0) years, median hospital stay was 15.5 (22.0–30.5) days. Successful and complete lead extraction was achieved in all patients. Thirty-two (65.3%) had received antibiotics prior to blood sample. Only in 31 (63.3%) positive culture results were seen. The most common isolated pathogens were Staphylococcus aureus (23.5%) and coagulase negative staphylococci (23.5%). Other bacteria were isolated considerably less often. The atrial lead was most common location for lead vegetations, seen in 50.0% of cases. Five (10.2%) patients have died due to the disease. Conclusions: Lead-related infective endocarditis is a major complication of cardiac implantable electronic devices with considerable morbidity and mortality, which in our study was as high as 10.2%.
  • No Thumbnail Available
    Item
    A new training set-up for trans-apical aortic valve replacement
    (2009-06) Abdel-Sayed, Philippe; Kalejs, Martins; Von Segesser, Ludwig Karl
    Trans-apical aortic valve replacement (AVR) is a new and rapidly growing therapy. However, there are only few training opportunities. The objective of our work is to build an appropriate artificial model of the heart that can replace the use of animals for surgical training in trans-apical AVR procedures. To reduce the necessity for fluoroscopy, we pursued the goal of building a translucent model of the heart that has nature-like dimensions. A simplified 3D model of a human heart with its aortic root was created in silico using the SolidWorks Computer-Aided Design (CAD) program. This heart model was printed using a rapid prototyping system developed by the Fab@Home project and dipcoated two times with dispersion silicone. The translucency of the heart model allows the perception of the deployment area of the valved-stent without using heavy imaging support. The final model was then placed in a human manikin for surgical training on trans-apical AVR procedure. Trans-apical AVR with all the necessary steps (puncture, wiring, catheterization, ballooning etc.) can be realized repeatedly in this setting.

DSpace software copyright © 2002-2025 LYRASIS

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback